❄️【User-oriented Multiple Functions Modes: 】This portable air conditioner offers cooling, dehumidifying, fanning and sleeping modes to meet various needs of users. In sleeping mode, this air conditioner will become quiet (Noise≦52dB). It’s able to maintain the temperature while you are sleeping.

❄️【Convertible Fan Speed and All-day Timer:】Under the fan mode, there are 2 fan speeds accessible, and you can set the high or low speed as you wish. There is an energy saving 24-hour programmable timer, allowing the air conditioner unit to shut down automatically once reaching the usage time.

❄️【Strong Air Flow Rate and Wide Coverage:】The compact 8000BTU/H air conditioner unit delivers fast, effective cooling for spaces up to 400 Sq.Ft in home, office, cabin or camper. It comes with a strong air flow rate of 300m3/h that ensures air circulation and replaces with the outdoor fresh air in a few minutes.

❄️【Water Full Warning and Long Drain Hose:】Among various protection functions, this unit is designed with a water-full control and warning, keeping your floor or carpet from getting wet. The drain hose provided is long with a length of 10ft, allowing you to drain the water to the bathroom easily.

❄️【Easy Moving Casters and Remote Control:】At the bottom of the air conditioner, there are four all-direction casters, allowing it to roll freely from room to room. It's worth mentioning that the air conditioner features a modern design that everyone loves, the remote control, that allowing you to set it up conveniently.

When should the drainage pipe be used, and will the air conditioner shut down automatically if there is excessive water inside?

Under normal circumstances, we recommend using the drain pipe when continuous drainage is required, such as in high humidity environments or when frequently prompted to empty the water tank. The unit will automatically shut down if excessive water accumulates inside.

Where to insert drainage pipe? Is it okay to insert drainage pipe while the air conditioner is on? Or I need to turn off the air conditioner, then insert drainage pipe to let water flow out?

Please refer to the attached picture. You can connect the drain pipe to these two drain outlets. It can be attached while the air conditioner is running. Simply unscrew the cap on the drain outlet and push the drain pipe onto it.

A couple of questions regarding setting up the air conditioner. Without missing parts, I am not able to do. Also do I use tape to make sure no air is leaking in connecting parts? I have difficulties to connect these parts, what to insert tubes? How to drain the internal water, where to find water tank?

The pipe connections will not leak as long as they are tightened. No tape is needed. The drainage pipe can be inserted into the drainage outlet. The air conditioner does not have a water tank when moved.

The dehumidification performance of my portable air conditioner is poor at around 18°C, but the outlet still blows cold air. Is this a malfunction?

This is normal. The dehumidification function of an air conditioner cannot be compared to that of a dehumidifier. When operating at low temperatures around 18°C, the unit will repeatedly frost, defrost, and shut down. As long as the set temperature is lower than the ambient temperature and the front outlet blows cold air, the cooling system of the unit is functioning normally.

Has to drain the unit consistently. Every couple hours has to drain the item.

It is recommended to connect the drain hose so that continuous drainage is possible.

the unit is knocking out the power in the house.

Could you please change the socket to see whether this situation will happens again?

If this still doesn't work, it maybe the problem of the internal wire.

The machine is faulty, it is turning on and off, switching between cycles

Here's why this issue happens:
1. The use of the environment is too humid (long-term humidity of about 90%), the electric control board is damp.
2. The light is too close (less than 1.5m), or there is other electrical interference around.
3.Try tapping the top of the machine with your hand to see if it will woke normal
Could you check and get back to me ?

E1 code

Please remove the front cover and back cover, and then check the plug that connects the sensor, and re-insert it to see if it works.

Here is a video for reference: https://youtu.be/Uwrp6qPtEsY

Does this unit require emptying a drain pan?

The product has an upper drain and a lower drain. The upper drain can be connected to the drain pipe to drain water, and the lower drain is directly inclined to pour water from the machine.

I have a E1 error message what do I need to do?

Please remove the screws, remove the front cover and back cover, and then check the plug that connects the sensor, and re-insert it to see if it works.
Here is a video for reference: https://youtu.be/qXbaAzIXp7

the swing not moving, it's only on one direction!!

Can only move up and down

Show E4 code error

E4 means the item automatically turns on the antifreeze protection.
This code error will disappear on its own after you not use it for a while.
You can turn off the product, unplugs the power and leaves it for a few hours.

Install correctly but blow the hot air

Take a video of the led screen and the compressor on the back
Press to cool mode to see if the compressor is working

I also noticed the manual states that I cannot use a plug adaptor or an extention cord, I do have a heavy duty extension cord nor a regular one or can I use a separate power strip and only plug the unit into that?

You can use a separate power strip and plug the unit into that.

We have drained it twice. It worked for a short time & then the FL code is back.

Make sure that the water is drained. When it can be drained, you can tilt the product back to ensure that the water is drained. After draining, the water plug is plugged back tightly. Turn off the power for a few minutes and then turn it on again.
If it still doesn't work, please send a video and try to see the water level line of the water tank and the led screen

Too loud and not working as expected, set up at 20degree for 4 hours room temperature still at 25degree.

Did you connect the hose?
Could you please tell us the temp on this condition?
Is there cool air blowing?

Item is not working

Here is the assemble picture attached.

How to drain and exhaust? can you open the drain directly without connecting the water pipe to drain the water, and use a basin to collect water?

The product includes an exhaust pipe and a drain pipe, as shown in the picture, the left side is the exhaust pipe, and the right side is the transparent drain pipe.
Water can be collected under the machine with a basin.

The air conditioner won’t turn on .

Please check according to the following method first
1. If there is no electricity, connect it to a power socket and turn it on.
2. Water full indicator light is on to exclude internal water storage.
3. It is recommended to be used at ambient temperatures between 5 and 35 degrees Celsius.
4. In cooling mode, the room temperature is lower than the setting temperature. Change the setting temperature.

The Portable Air conditioner is too loud.

Is the machine still cooling? Generally, if there is a problem with the cooling function, it is broken. If the cooling is no problem, the mobile air conditioner will have a louder sound because the compressor is inside.

What is the Weight ?

It's 48.94 lb

How do I unplug the water stopper?

The water plug is at the bottom of the back and rotate to remove it.

Does this unit require an exthaust tube?

Yes, it needs an exthaust tube that our item included.

Please supply a video explaining how to install model # EP24937 into a sliding window.

https://youtu.be/fXKfndzKkIE

it does blow cool air. My question is why does it not stay at 62 degrees. Is it not working correctly because it jumps back into the 70s?

After setting the temperature, it will change to show the room temperature . The set temperature will not always be displayed, but the room temperature will slowly drop , please do not worry

I have attached the drain hose to the lower drain plug, but not sure if I should hook the rest of the hose to the upper drain plug. The instructions don't really state which drain plug is best, they only show hooking up the lower. What is the difference between the upper and lower? Should I just leave the plugs in and drain manually or what?

Just plug in the drain pipe below. In fact, you don’t need to plug it in. When the water is full, the machine will display FL. Just put the water out at that time.

The air conditioning system that was recently purchased is the wrong order because on the equipment it says that it’s 5000 BTUs when I ordered a 10000 BTU?

There are two different values because the detection standards are different. One is ASHRAE standard and one is DOE standard ,But they are the same BUT.

It just shuts off after 45 minutes to one hour and will not restart even if the room reached 78 degrees.

Please make sure that the display is still on or the display is dark It's dark. Maybe the guests shut it down regularly, If it's on, ask about the set season and the ambient temperature

It will cool to the set temperature, then stop. It will not cool again until we change the temperature setting or restart the air conditioner.

The temperature control system should be able to be turned on again after elevation The sensor is different from the human body. The temperature sensor will not work again until it detects a high temperature in the surrounding area