Portable Air Conditioners, 12000 BTU 4 in 1 AC Unit with Cool, Fan, Heat & Dehumidifier

Regular price $359.99 USD
Earn 360 points
Estimated Delivery

Portable Air Conditioners, 12000 BTU 4 in 1 AC Unit with Cool, Fan, Heat & Dehumidifier

$359.99 USD
ColorWhite
MaterialABS
Overall Dimension17.5" x 15.5" x 31"(L x W x H)
Cooling Capacity (ASHRAE)12000 BTU
Heating Capacity10000 BTU(ASHRAE)
Recommended Cooling Area450 sq. ft
Air Flow410 m³/h
Wind SpeedHigh/Medium/Low
Dehumidifying Capacity64 Pints/Day
Adjustable Temperature Range60.8℉~89.6℉
Timing Range1-24 Hours
Noise Level≤56dB
Voltage115V 60Hz
Exhaust Hose Length5 ft
Drainage Hose Length25.5"
Power Cord Length6 ft
Applicable Window Size Range25.5"-47"
Net Weight70 lbs
1 x Portable Air Conditioner
1 x Remote Control
1 x Hose Connector
1 x Exhaust Hose
1 x Drainage Hose
1 x Window Kit Adapter
1 x Window Kit
1 x User Guide

4-in-1 Design & Powerful Cooling: Combining cooling, heating, fan, and dehumidifying functions, this portable air conditioner can meet your different needs and work all year round. With a 12000 BTU high cooling capacity and 70° auto swing function, this portable ac can cool down an area of 450 square feet evenly and quickly.

Smart WiFi Control from Anywhere: You can download the Smart Life App to control this AC unit from anywhere. And it also works with Amazon Alexa, which allows you to change all settings with simple voice commands. Besides, the LED touch control panel and handy remote control are helpful for you to manually control the portable AC.

Quiet Operation & 1-24H Timer: Equipped with a high-efficiency compressor, this stand-up unit runs at a low noise level (≤56dB) and is more energy-saving. You can turn on the sleep mode and set the auto-off time from 1-24 hours to have a peaceful and comfortable all-night sleep.

2 Drainage Methods & Efficient Filtration: This 4-in-1 portable AC unit features an upper drainage hole and exhaust water pipe for continuous drainage and a lower drain plug for convenient manual drainage.

Easy to Install & Move Around: Our portable air conditioners come with a sliding window kit and detailed instructions for simple installation. And it fits well with any vertical or horizontal sliding windows (suitable window size: 25.5"-47"). What's more, with 4 universal casters and built-in handles, you can move the AC unit anywhere easily.

Description

Our 4-in-1 portable air conditioner features cool, heat, fan, and dry modes as well as 3 fan speeds to meet your different needs. Also, the high cooling capacity offers rapid cooling for the spaces like living rooms, bedrooms, and offices. Except for the control panel and included remote control, this portable air conditioner can be controlled by a smartphone app too. With the built-in sleep mode and a 24H timer, you can enjoy peaceful sleeping and cool air at the same time. The installation is easy with instructions and included a window kit the AC unit is suitable for most double-hung or single-hung windows and sliding sash windows. When you move the unit, the casters and handle would help a lot.

Features

  • High cooling capacity for the large cooling areas and fast cooling
  • The angle of the fan blade can be adjusted automatically
  • Features 5 operating modes and 3 fan speeds
  • Builtin 1-24 hours timer to auto shut off the unit
  • Easy mobility with recessed handle and smooth casters
  • The control panel is equipped with an LED display
  • Includes handy remote control for convenience
  • Can be controlled by a smartphone app
  • Easy to install with instructions and accessories
How do I replace the power cord of the mobile air conditioner?

Before replacing the power cord, please disassemble the unit first. Refer to the disassembly video at https://youtu.be/Y9X5wItBlR8 , and refer to the power cord replacement video at https://youtu.be/9VRHL33_0bY for the replacement procedure.

Is there a universal Window kit adapter available for sale for the FP10115US-WH?

Yes, the universal accessory is FP10123US-WH-part 6. The price is CA$25 per set, excluding shipping costs.

Is there any video showing how to replace the air outlet deflector blades?

https://youtu.be/8CZZwjUA9vE

The wheel is broken.

You can send FP10123US-WH-part 5.

In heating mode, when the device initiates the heating cycle, multiple (inconsistent) clicking sounds can be heard before the device is actually turned on and begins to heat up.

It makes a few noises only before the heating starts, and then the heating function operates normally. Most likely, these are the normal operating sounds of the four-way valve and the relay, so it doesn't represent a malfunction.

When using the heater, is it necessary to vent the exhaust outside? Or can the hose be removed to allow the warm air to circulate indoors?

The exhaust pipe must be connected and vented outdoors.

What causes the flashing error code 8.8, and how can it be resolved?

The display board may be faulty; it is recommended to replace the entire motherboard.

What is the heating energy efficiency, for example the COP or HSPF value?

The COP value is 3.11.

I’ve had the experience a weird oder coming from it. I am unsure if it’s a mold issue. The only mode I’ve used was the ac and I did drain it manually and there wasn’t much water to drain. Need to know if there’s been issues with these getting mold?

1. Inadequate Cleaning
Dust and hair accumulated on the filter, evaporator, and condensate tray can foster mold and bacteria in humid environments, resulting in musty or unpleasant odors.
2. Condensate Issues
Stagnant condensate water that fails to drain promptly can become stagnant and produce a foul smell. Clogged drain pipes may also cause accumulated water to backflow, exacerbating odor problems.
3. Other Factors
The air intake may absorb external odors such as cooking fumes or pet smells, introducing them into the system.

There are persistent clicks just before it starts heating if room temperature falls below the set temperature, and l'm concerned there's some sort of malfunction.

The clicking sound you hear just before the unit starts heating when the room temperature falls below the set temperature is normal. This sound is caused by the 4-way directional valve operating, which is typical during the heating process. There is no need to worry, and this clicking does not indicate a malfunction.

Will the machine display any indication if the water reservoir is full?

If the water reservoir is full, the machine will display an FL or FT code as a warning.

Once the set temperature is reached, will the fan continue to run after the compressor is turned off, or will it become quiet until the compressor restarts?

This is a fixed frequency machine, the fan doesn't turn.

The fan has started to make a loud noise and the heat function no longer works.

Mobile air conditioners are a one-piece design with an internal and external unit, and the compressor works inside, so it will be slightly louder.

Is this normal when it was used before?

Can you check which part is making the noise?

Are the base plate fastening screws loose?

What is the ambient temperature and setting temperature in heating mode?

Has the filter been cleaned?

Is the exhaust duct installed properly? Please wait a little longer for heating.

It works fine on cool mode but not heating.

The description provided refers to the cooling function working but not the heating function. Check if the four-way valve is not activated. Instruct the customer to switch from cooling mode to heating mode, set the temperature to around 30 degrees, the four-way valve will make a "click-click" sound when activated, have the customer listen for this sound. If there is no sound, it can be concluded that the four-way valve is not functioning, and it will need to be replaced.

Feedback from customers the machine was working fine at first, after working for a while the compressor turned off and only the fan was running.

Can you help us ask the customer how long the compressor shut down after the machine had been working?
Either the ring temperature has reached the set temperature and the compressor stopped.
Either the compressor has stopped, or it has overheated and jumped out of the machine for protection.
Could you please check with the customer what temperature they have set and what is the ambient temperature? Is the exhaust duct connected smoothly? It is better not to have big bends in the exhaust duct.

A rusty crack appeared behind the back plate of the machine, causing water to leak underneath the unit.

This position can not change the accessories, you can ask the guests have tools (glue, plastic plate) and so on, to plug up the gap to try

This machine is leaking

1、Check the upper and lower water plug plug tight or not 2、Look at the lower water from where it flows out, is not the lower water plug mouth blocked 3、The bottom of the base to see if it is leaking?

purchased an 12,000 BTU but I got an 8,000 BTU.

This is the Ashrae 12000 SACC 8000 standard, which is different

Does this model have an integrated inverter?

This model is fixed frequency, not variable frequency,

How many watts or amperage does this appliance draw in normal operation?

Rated current 10A
Rated power almost 1135W

Remote turning on but not working on the item.

The remote control receiver board is in this position, please align this position to control the machine.

Is there any way to monitor the power consumption of this unit via app or any other way?

There is no app to monitor the power consumption.

What are the dimensions of the window kit?

Applicable window size range:25.5"-47".

What btu does it cool and what btu does it heat?

12000 BTU for cool and 10000 btu for heat.

the continuous drain feature illustrated on page 13 of user manual does not function, how do I get this feature to operate?

The first one is not to connect the drain. In this case, the water will be collected in the internal water tank. When the water is full, there will be a prompt sound. Please open the cover of the drain hole and pour it out.
The other one is to connect the drain pipe. In this case, there is no need for manual drainage, and it will automatically drain.

What's the diameter of the drainage hose?

The diameter of the drainage hose is 0.6".

What's the diameter of the exhaust hose?

The diameter of the exhaust hose is 6".

The heater in the unit does not work and will make a clicking sound when trying to start

First check whether other modes are normal. If they are normal, they may be caused by frequent mode switching. After a day of inactivity, try the heating function again; If there is still a problem, the four-way valve may be broken and the customer cannot repair it

If we need to have the exhaust hose connected to unit when we are using the heat mode?

Yes.

Do you know the current draw for this portable AC at 12,000 BTU?

Rated power is about 1200W

it's not cool enough

What is the setting temperature, ambient temperature and room size; It is suggested that the guests should close the doors and windows to reduce the area as much as possible

when I press sleep mode, nothing happens. Is it a faulty unit?

The effect of sleep mode is that the temperature rises by 1℃ per hour, instead of lower the sound.

It keeps showing FT on the screen.

Please try to pull out the water plug in the lower part of the fan and let the water flow out. Then turn the machine on again to see if it can work normally.
If not, we will suggest you take apart the fan to reinforce the red port as the video in attachment.
You need just remove the outer cover of the item and then remove the lid of the electronic box. Then you will see the red port.

Do I have to have a basket to drain the water? Or it has the built-in container, I just need to clean it regularly?

There are hardly any containers in it to hold water. To be connected to a drain pipe, or gravity drain. there will be a buzzer when the water is full