Tangkula 10000BTU Portable Air Conditioner, with Drying, Fan, Sleep Mode, 2 Speeds

Regular price $229.99 USD
Item is in stock

Earn 0 points on this purchase.

Learn more
Color
White
Estimated Delivery

Tangkula 10000BTU Portable Air Conditioner, with Drying, Fan, Sleep Mode, 2 Speeds

$229.99 USD
ColorWhite/Grey/Blue
MaterialABS
Product Dimensions12" x 12" x 27.5"(L x W x H)
Cooling Capacity10000 BTU
Coverage Area350 sq. ft.
Air Flow Rate290 m³/h
Voltage115V/60Hz
Temperature Setting Range60.8℉~89.6℉
Timer1-24 Hours
Wind SpeedHigh/Low
Noise≤55dB
Exhaust Hose Length62"
Exhaust Water Pipe Length25.5"
Net Weight48.5 lbs
Power Cord Length6FT

10,000 BTU Cooling Power: 10,000 BTU portable air conditioners feature four modes----cool, dry, fan, and sleep mode, it is fast and effective cooling for rooms up to 350 square feet. Temperature can be adjusted between 60.8˚F and 89.6˚F for various purposes.

Easy to Operate: With an LED display and remote control, the portable floor air conditioner is easy to set time, temperature, and mode. Four castor wheels make it easy to move. The portable ac is ideal for dormitories, apartments, campers, offices, living rooms, or bedrooms.

Effortless Installation: Our portable AC comes with a window kit, which is suitable for double/single hung windows or sliding slash windows no more than 47” long/wide. Just attach the included hose & window adapter, and plug it into an outlet. You can enjoy a cooling summer day!

Safety Protection: Child lock and grid design are perfect for ensuring the safety of loved ones. Auto-defrost function and overload protection are effective for energy-saving. It has passed ETL & DOE certification.

What’s Included: 1 x Portable Air Conditioner, 1 x Remote Control, 1 x Hose Connector, 1 x 62" Exhaust Hose, 1 x Drain Hose, 1 x Window Kit Adapter, 1 x Window Kit, 1 x User Guide

Description

Enjoy a cool and fresh summer with our 3-in-1 portable air conditioner! With a 10000 BTU high cooling capacity, this portable AC unit can efficiently cool areas up to 350 square feet, which is suitable for the living room, bedroom, dining room, office, etc. In addition to cooling your room, this air conditioner can also serve as a fan and dehumidifier to meet different needs. Our air conditioner features a removable and washable filter screen to provide clean air. This AC unit is designed with 2 adjustable fan speeds (Low/High), an adjustable temperature of 60.8°F-89.6°F, and a 1-24H timer to meet different needs. Besides, the clear LED display, touch panel, and remote control allow you to operate the air conditioner effortlessly. The sleep mode and quiet operation ensure a peaceful and comfortable sleeping environment for you. With 4 universal wheels, you can easily move it to any place.

Features

  • 10000 BTU powerful cooling capacity can cool down an area of 350 sq. ft.
  • The louver can be manually adjusted up & down 90°, automatically left & right 60°
  • 3in-1 design includes cooling, fan, and dehumidifier to meet different needs
  • 4 universal casters and builtin handles for easy moving around
  • Sleep mode with low noise ensures a quiet and comfortable sleep
  • Easy to operate with smart touch panel, LED display, and remote control
  • 124hour timing function prevents waste and saves energy
  • Safety child lock prevents potential accidents to cause danger
Why does the air conditioner sometimes run, shut off for a few seconds and restart, while at other times it fails to start cooling directly?

The issue may be caused by a faulty ambient temperature sensor that needs replacement. The universal part number is FP10260US-WH-P1.

It is not used just opened once and its spreading foul smell

It may be moldy inside. Clean the filter and let it dry. If it doesn't work, disassemble the machine and check the inside. It's also possible that there is a smell in the storage environment

It is working fine on the fan mode, but as soon as I try to enable cool mode, it runs for a second and shuts off.

This situation might be due to a lack of fluorine or a compressor failure. It is necessary to have it checked by a repair person.

It can no longer function―it doesn't power on, nor can it be turned on.

If there are no lights on the control panel, it means the system is not powered. Check if it has been used. I just received the information and can check the wiring (disassemble the unit to inspect the internal wiring of the electronic control box for any loose connections). If it has been used, it may need to replace the electronic control (the motherboard or display board; generally, the motherboard has a higher failure rate).
Disassembly video: https://www.youtube.com/watch?v=x1JA05trM_8

The product doesn't cool, I drained the water, cleaned the filter, and tried to reset it. I set it to the lowest temperature for 2 minutes, then stopped it. It runs randomly for up to 5 minutes, then turns off, and then is turned on again every 10-20 minutes, sometimes not even on at all. What should I do?

It might be a malfunction with the ambient temperature sensor, which needs to be replaced.

After running for a while, there is a foul smell of sewage. Other than that, it operates normally. Water has been drained according to the instructions received at the time of purchase.

Check if it's placed near the sewer pipe or floor drain. Move it to a different location. This might be affected by environmental factors. If it still doesn't work, remove the filter and exhaust pipe for cleaning, and inspect the inside for any mold.

exhaust hose size

Please check the attachment

What is the wattage?

It is around 900W.

it will not switch from numbers 1-32 and does not do anything when changing mode.

Set the temperature range to 16-32 degrees Celsius, which can only be changed within this range.
Perhaps the machine's response time also needs some time, so wait and see if there are any changes when switching modes.

Getting E2 message.

Replace the defrosting temperature sensor.
Attached are the videos about the position of the defrosting temperature sensor and how to replace it.

What is the refrigerant type?

R32

I got an FT code after unit stopped. Emptied it, cleaned filters but it turns on and blows no air. What am I missing?

Maybe the float of the water level switch is stuck. Try shaking the body hard to see if it can be restored. If it still doesn't work, you need to dismantle the machine and adjust the water level switch. Pull down the float and move it. Video: https://youtube.com/shorts/ifJBZjdBuFk

have purchased this AC but my window opens outside horizontally. The fitting kit came with AC doesnot work. Window size: 64” height and 20” width. Since it open horizontally there is no way I can fit AC.

You can buy an isolation cover online and install it yourself
Here is the installation video.

Do I need to put grill or any cover to the outside exhaust hose/vent because I am worried that some insects might go inside the vent?

There's no need to put grill or any cover to the outside exhaust hose,if installing,it actually hinders the cooling effect.

Can the dehumidification and air conditioning functions of a mobile air conditioner be used simultaneously?

No,it can't.

Can both dehumidifier and air conditioner works at the same time?

No,it can't.

in humidification mode ,the product do not respond when Press the button.

The buttons have no issue, and the temperature and wind speed are not adjustable in humidification mode. please try whether the buttons can be used normally in other modes.

show error code Ft.

It need to empty the drain pan by removing the rubber plug.

Can you at least tell me how can I clean the filter

Please see attachment to see the steps.

Where the a/c will go is close to a wall furnace but it' stoo hot to have the heat on. I that a safe place?

If it's too hot, don't lean them together, otherwise it will affect the use due to overheating protection.
Mobile air conditioners can be moved and can be placed further away.

The installation manual states that when adjusting the flexible exhaust hose the "height from exhaust hose to the floor must be more than 35".I cannot do this because my bedroom window is small and located near the floor. The maximum height from the exhaust hose (in the window) to the floor is only 18". Can I safely operate the air conditioner with a floor-to-hose distance of only 18"?

As long as the exhaust pipe is not bent at a large angle, the impact will not be significant if your window is only 18'' high.

Missed the window kit

Send FP10123US-WH-part 6 Window kit (1set)

Will the air conditioner indicate if the water tank is full?

there will be a prompt when the water is full.

Does this air conditioner have a water tank?

The air conditioner does not have a water tank, but it has a place inside to temporarily store water.

Is the unit is self evaporating?

This air conditioner cannot evaporate all the water, and still needs to be drained manually

After stopping at the set temperature, the machine will not start again when the ambient temperature is higher than the set temperature.

If the ambient temperature is close to the set temperature, it is normal that the machine will not start automatically, because the temperature sensor is not so sensitive and can only detect the temperature around the machine.
Please set the temperature lower, so that the temperature sensor can detect the temperature rise more easily, and then automatically turn on the machine after the temperature rises.

Video of replacing sensor

Here attached a video for reference, please check.

getting E2 error for this unit

Check connection or replace it. To clean or replace the temperature sensor. Here is a video for reference: https://youtu.be/SrvAllXEseU

I understand that it's safe to plug in and turn while I'm home and awake. But is it safe to plug it in, turn it on, and then leave my house for the day?

Generally, there shouldn't be any problems when plug it in, turn it on, and then leave house for the day,

but it is not recommended to do so if it runs for a long time and is left unattended.

does it come with a heater?

It doesn't have heater

when the dehumiidfier is it on, does it make the tempaerature cooler?

The dehumidifier has little effect on temperature

The remote controls the power on, but the air conditioner doesn't respond when you press the off button

Power on and off are the same button, since it can be opened, it should be able to close, please wait for a while, the compressor is not so quickly shut down

How to clean the drain pipe?

You can just take the hose off and clean it, then put it back on.

Cx had problem with the AC, every 24 minutes the air-conditioned automatically turns off and she don't want to wake up every 24 mins just to turn on the AC again.

Does the customer set the timed mode? Pls set the cooling mode temp turned down to the lowest to see if it does the same thing.

1. Can I use the dehumidifier and cooling at the same time? 2. Do I need to remove the screen from my window when puting the exhaust hose? 3. If the drained water is already full, will it automatically shut down?

1. The dehumidification mode and refrigeration mode of the air conditioning are two separate modes.
2. There is no need to remove the screen window, which does not affect the installation of the exhaust duct.
3. It will automatically turn off when the water is full.

How to change from celsius to fahrenheit and I would like to know if there is a water level indicator.

Mobile air conditioner: long press mode MODE button to switch between Fahrenheit and Celsius. The remote control can also operate it. This one doesn't have a water level indicator.

What does it mean on the power button light blinking; could not find it anywhere in your manual?

There are two possibilities:
1. problems with the electronic control, moisture or damaged in transport.
2. If the machine is used for a period of time, after flashing can continue to run, that is the machine in the frost, is normal.

If it's normal that exhause hose is getting hot?

It's normal for the exhaust to get hot because it has to absorb the hot air and exhaust it outside before cold air blows inside.

assembly video

https://www.youtube.com/watch?v=SAFNVgyXO3w

What is the minimum and maximum length of the adjustable window kit?

It is 25.5"-47".

Do you have to empty the water container when this unit is used in air conditioning mode?

Yes,you have to empty the water container when this unit is used in air conditioning mode.

Can the vent go up vertically and vent into the attic?

The exhaust hose should be installed on the window and cannot be installed vertically, which will affect the machine's operation.

What amp does this draw when cooling?

It's about 7.8A.

It was not stated Ashrae or SACC standard.

Two standards, please see the attachment.

Wheels of which model could be sent for this air conditioner?

Wheels of model FP10123

what is the condensation capacity?

It's rated as 10000 BTUs based on the ASHRAE standard and 7000 BTUs based on the SACC standard.

It doesn't cool.

A Make sure that the installation method is correct. Due to the working principle of the mobile air conditioner, the product must be connected to the outside of the window to absorb the hot air, so as to convert into cold air.
B It is necessary to confirm whether the cooling liquid is allowed to return after standing for 24h
C It is necessary to confirm the set temperature of the guest. The product needs to convert hot air into cold air. If the ambient temperature is very close to the set temperature, there will be no cold air. The guest needs to press the cool mode first and then set a lower temperature
D If it has been used for a period of time without blowing cold air: is there any sound of the compressor working, can you give a video, and the exhaust pipe is removed to see if there is air at the exhaust outlet, and the filter screen can be cleaned

Please explain this statement from page 14 in the User’s Manual: From the section, “In cool mode”…

In Sleep mode, for example, if you set it at 20℃, after 1 hour the preset temperature will increase by 1℃, and after
another hour the preset temperature will again increase by 1℃. Then the temperature will not increase.

After assembling and operating according to the instructions, the product did not cool or cool down its surroundings for seven hours

This could be a refrigerant leak.