Portable Air Conditioner, 14000 BTU 4 in 1 AC Unit with Cool, Fan, Heat & Dehumidifier

Regular price $389.99 USD
Sale price $389.99 USD Regular price $571.99 USD
32% off
Hurry! Low inventory

Earn 0 points on this purchase.

Learn more
Estimated Delivery

Portable Air Conditioner, 14000 BTU 4 in 1 AC Unit with Cool, Fan, Heat & Dehumidifier

$389.99 USD Regular price $571.99 USD

Details

❄️【4-in-1 Design & Powerful Cooling】Combining cooling, heating, fan and dehumidifying function, this portable air conditioners can meet your different needs and work all year around. With a 14000 BTU high cooling capacity and 70° auto swing function, this portable ac can cool down an area of 700 square feet evenly and quickly.

❄️【Smart WiFi Control from Anywhere:】You can download the Smart Life App to control this AC unit from anywhere. And it also works with Amazon Alexa, which allows you to change all settings with simple voice commands. Besides, the LED touch control panel and handy remote control are helpful for you to manually control the portable AC.

❄️【Quiet Operation & 1-24H Timer:】Equipped with a high efficiency compressor, this stand up unit runs at a low noise level (≤57dB) and is more energy-saving. You can turn on the sleep mode and set the auto-off time from 1-24 hours to have a peaceful and comfortable all-night sleep.

❄️【2 Drainage Methods & Efficient Filtration:】This 4-in-1 portable AC unit features an upper drainage hole and exhaust water pipe for continuous drainage and a lower drain plug for convenient manual drainage.

❄️【Easy to Install & Move Around:】Our portable air conditioners comes with a sliding window kit and detailed instruction for simple installation. And it fits well with any vertical or horizontal sliding windows (suitable window size: 25.5"-47"). What's more, with 4 universal casters and built-in handles, you can move the AC unit anywhere easily.

Download and install the App-Smart Life.W

hen WIFI indicator flashes, select “Add Device”-“Large Home Appliances”-“Portable Air Conditioner (Wi-Fi)”, and follow the instructions on the display. Or you can open the Bluetooth of your mobile phone, and the device will automatically connect with Bluetooth.I

f the WIFI indicator flashes rapidly, it can be connected directly.I

f the WIFI indicator flashes slowly, press “Go to Connect” to connect the WIFI named “SmartLife-XXXX”.

It's sort of a loud click when the unit shuts off. It is intermittent. Is it normal?

When a portable air conditioner is turned off, the refrigeration system does not come to an immediate, complete halt. After the compressor stops running, the high-pressure gaseous refrigerant within the lines must redistribute to equalize pressure; this process generates sounds that are more noticeable than usual.
You can compare the sounds you hear against the following examples; if they fall into these categories, they are considered normal:
"Gurgling" or "hissing" sounds (like flowing water or air): These are caused by the refrigerant flowing through the lines and the pressure equalizing; this is the most common sound heard after shutdown.
"Clicking" or faint "crackling" sounds: These are usually caused by the thermal expansion and contraction of internal plastic components due to temperature changes; this is also a normal physical phenomenon.
Normal post-shutdown noises are brief. You can observe the situation: if the sound gradually fades and disappears within a few minutes, there is no cause for concern.

What is the diameter of the exhaust hose?

The hose diameter(External interface size) is 155mm(6.1”)

does this unit heat with resistance coils or inverter heat pump for high efficiency?

Four way valve switches refrigerant flow direction to achieve heating effect

Video of replacing the keyboard panel:

https://youtu.be/K-XJKfjrSNg

Is it a variable-frequency air conditioner? What is the power in watts?

Fixed-frequency air conditioner, with a power of around 1300W

How to turn on the child safety lock?

This product does not have a child lock.

How to turn on child safety lock?

The top cover control panel features a child lock button. Press and hold it for 3 seconds to activate the lock, and the child lock indicator light will illuminate accordingly.

How many square feet of area can this device heat at a temperature of -12 degrees Celsius (10 degrees Fahrenheit)?

The operating temperature of the machine is 5-35 degrees Celsius. The machine cannot function at -12 degrees Celsius.

After turning on the air conditioner, it operates for at most half an hour before causing the circuit breaker to trip, thereby cutting off all power. No other appliances were turned on today, yet it still causes the circuit breaker to trip and stop working.

The air conditioner should be connected directly to the wall socket, not through a extension cord.

Disassembly video:

https://youtube.com/shorts/oiVqKV5e9Ww

How do I turn on Wi-Fi? I tried holding down the timer button to activate Wi-Fi, but it didn't work.

First, download the APP from the instructions, and then follow the steps shown in the illustrations.

How to replace a fan?

Here is the video of the replacing the fan: https://youtube.com/shorts/1Fk9Hp0AShQ

This product does not have a heating function; only air comes out, but no hot air.

1. Make sure the unit is switched to heating mode.
2. The set temperature is too low: when heating, the set temperature should be higher than the ambient temperature.
3. The anti-cold wind function is activated: during the initial stage of heating, the air conditioner will preheat the internal heat exchanger to prevent cold air from blowing out. This process lasts for 1-3 minutes and is a normal phenomenon; please wait patiently.
4. Check whether the air intake or air outlet is blocked.
5. An excessively low ambient temperature may also cause reduced heating efficiency of the heat pump.
6. If all of the above are normal, the problem might be related to a core component.

The unit won't stay on AC mode, doesn't matter how low I set the temp. It does not keep the room cool. Once the temp is met it shuts off but does not come back on automatically when the room heats up. I had it set for 69° and it reached 75° and the AC did not come back on. I have to keep resetting it.

Replace the Ambient Temperature Sensor.

Discovered a crack on the bottom that the water is leaking out of.

This foam provides insulation and prevents condensation.

Could you try using plastic adhesive, super glue, or all-purpose adhesive to patch up the base and see if it works?

I wonder what is min. max. in inch of the window kit.

There are two window panels, each 65CM(25.59 inches), suitable for windows no more than 120CM(47.24 inches).

How to replace the Defrosting temperature sensor?

Position of the Defrosting temperature sensor: https://youtube.com/shorts/HaoclMnuRc8?feature=share. Replacment video for the Defrosting temperature sensor: https://youtube.com/shorts/gqYZ8jzReP0?feature=share.

It was working great before but now when uses it turns it on for a couple of minutes and shuts the electricity off , no error codes.

1. The current may be unstable. Please try to change other sockets to see if the item will work properly.
2. It may be an overheating protection. Check whether the exhaust duct is connected and whether the exhaust duct is smooth.
Please also check if the hot air is discharged successfully and whether the machine is too close to the wall so that it cannot take in air?
3. It may also be a compressor failure.

What is the amp draw for heating & cooling?

Heating: 9.5A
Cooling: 11.5A

Does this unit use inverter technology?

There is no inverter technology.

It had a strange noise (sounding like a fan grinding sound) which persisted when the Aircon was turned on.

Could you please try the fan mode to check whether there is such a noise? If there is no noise in the fan mode, then there is something wrong with the motor or the water pump.

Can't work anymore. No cold wind blowing out.

1. It is necessary to confirm whether the machine is placed upright when it arrives. If it is upside down, it should be left to stand upright for 24 hours to allow the refrigerant to flow back before it can be used.
2. Confirm the set temperature and the ambient temperature of the guest. If the ambient temperature is very close to the set temperature, no cold air will be produced.
3. Check if there is any sound of the compressor working (the video is too short, but it seems there is a sound later). Remove the exhaust duct and check if there is any air coming out of the exhaust port.
If none of these steps have any effect or it is impossible to determine, ask the guest to switch to the cooling mode and set the lowest temperature directly. Wait for a while and measure the temperature at the exhaust port. If it is indeed at room temperature and no cold air is produced, then it is broken.

Error code as the picture shows.

This is full of water. See if the water can be drained. If the error message still appears after draining the water, the water level switch may be stuck. You can try shaking the body vigorously to see if it can be restored. If it still doesn’t work, you can only disassemble the machine and adjust it manually.

What type of refrigerant is used in this product?

R32

Who is going to install the new cord or how to install the new cord ?

You can refer to these video to replace the power wire after you receive it .
https://youtube.com/shorts/fRqjI_UkRa8?feature=share
https://youtube.com/shorts/DszDokLjUgg?feature=share

The unit is supposed to be used as AC or a heater but only the AC is working. The heater unit will not operate and blows cold air

Please check if the four-way valve is activated or not. Let cx switch it from the cooling mode to to heating mode, set about 30 degrees, the four-way valve will start “click” “click” sound, let cx listen to whether there is this sound. If not, the four-way valve is faulty and needs to be replaced.

The machine gets very hot on one side of the back close to the bottom,is that normal?

It is normal,it should be the compressor working.

I would like to know if it needs to be plugged in the window and set up for drainage on heat mode.

In heater mode , It also needs to be plugged in the window. The heating condensate is below, so it can only be drained manually.

. The humidity in the basement is between 50 and 54 % and after a day on dry mode barely no water coming out of the drain tube top or bottom as the compressor constantly coming on and off cool mode seems to work fine

Dehumidification mode of air conditioner, the programme sets the compressor to work for a period of time, stops for a few minutes, and the fan continues to run.
Portable air conditioner and dehumidifier dehumidifying capacity can not be compared, and portable air- conditioner condenser there is a water motor will hit the condensate condenser volatilisation, so if the machine's compressor is normal switching work, and the machine can be cooled, it is not a problem.

The temperature setting remains at 79 and cannot be changed. I can change the temperature on the remote but it can not be changed on the control panel.

Maybe the control panel wire is loose,

You need to dismantle the machine to check it.

What does FT error code mean?

FT is water full code, it means you needs to drain it .

How do I change the Fahrenheit to Celsius on my portable unit ?

Long press the up and down keys or mode key

How high off the ground is the drain hole in inches on the 14000 BTU model?

About 15''.

sometimes blow cold air and then switch to just warm air. I tried your instructions but it’s still doing the same. I turn it around 11am and it was blowing out cold until now its blowing warm air.

Compressor overheating protection may have caused the compressor to jump.

The fan is taking the heat out of the compressor so it feels like it's blowing hot air and the compressor is overheating.

Please make sure that there is no heat pipe connected, and that the air inlet is not blocked by anything that prevents air from coming in?

Are all of these units, same brand and model, that indicate in the user manual that drainage is only required for Dry mode, is this information false? Is drainage required at all times for moderate temperatures and regular humidity on Cooling mode?

Specifically, it is explicitly required to use a drain pipe to drain water in dehumidification mode. In refrigeration mode, some water will evaporate by itself, but it will still need to be drained after a long time or when the environmental humidity is high.

Can you send a video on how to remove a/c shell?

Please refer to this video to remove a/c shell . https://youtu.be/hHqi5ffyiaY

The temperature sensor is defective.

Send FP10115US-WH-part2-temperature sensor

I want to know if the diameter of the hose is a 5.9" diameter.

Yes.

How many decibels does it emit in normal day mode?

Cool mode:high wind 57dB, low wind 56dB
Heat mode:high wind 57dB, low wind 56dB
Fan mode:high wind 52dB, low wind 50dB
Dehumidification mode:high wind 57dB, low wind 56dB, sleeping: 56dB.

The drain hose was missing/lost

We can send the replacement part#4 (Corrugated drain pipe) under the SKU#FP10123US-WH

It unable to drain the water properly. They need to drain the water every 2-3 hours, or else the product will shut down. The customer attempted to use both the automatic and manual drain, but neither of them worked.

The condensate from the heating is underneath, so you have to drain it manually. There's also the possibility of high humidity in the environment, which could also affect it a bit.

What is the CEER for this unit?

7.7

Does heat function use heating element or heat pump?

It uses heat pump.

What type of outlet does this require?

please see the attached drawing.

How to turn the remote into C-F and F-C?

There is a button on the remote control to convert units

If I can use Drying (Dehumidifer) without having vent to outside?

Cannot.

the unit burned the wall outlet and the plug

It is likely that there is a problem inside the machine, which is a safety hazard.
It's completely broken

How to repair products that start blowing hot air after briefly blowing cold air?

Please self check and restart the machine first,
Firstly, check if there is any cooling air blowing after just one or two minutes of starting the machine. If there is cold air blowing, then hot air blowing will continue.
Please check if the exhaust pipe has air outlet (if the exhaust pipe does not have air outlet, the lower motor will not work); When the motor is not in the working room, the compressor cannot dissipate heat. If the temperature of the compressor is too high, it will automatically protect it. In this case, it is blowing hot air.
PS: Reasons for compressor automatic protection: a. Excessive temperature, b. Compressor overload (current and voltage too high)

Does it can be used without the window vent?

It can not be used without the window vent.